Contents

MAC 6 HEAD MASTER VALVE KIT K058 K059 Installation Instructions If either a Bohn or McQuay Mac 6 condenser is used with a Manitowoc GY1284NS the head master valve must be installed on the condenser at the time of installation Two kits are available from Manitowoc K058 for the Bohn condenser and K059 for the McQuay condenser Installation of K058 on the Bohn Condenser 1 Lubricate female fittings with refrigerant oil and install valve assembly on the right hand set of quick connect fittings on the Mac 6 2 Remove the middle and right hand bottom screws on the condenser bulkhead mounting plate install mounting bracket and replace screws 3 Using bolts washers and nuts provided bolt the enclosure head master assembly to the mounting bracket 4 Bolt ...